CMUS-9032
Features:
- LCD-display
- Pure sine output
- Case type (TOWER)
- UPS On-line class
- PF - 0.9
- On Self Test
- Cold start
- Microprocessor control
- Wide input voltage range
- Adapting to the current input frequency
- Intelligent management of the UPS cooling
- Adjustable battery charge current
- Various line-up of outlets
- The presence of EPO plugs for quick emergency power off
- Availability management ports: USB, RS-232, SNMP, RJ-11/45
- Protection against short-circuit, overload and other interference in the input power
- Charge the battery when the UPS is off
- Connecting additional battery kakbinetov
- Have UPS Isolation Transformer
Where to buy
|
|
Technology
UPS Type |
On-line |
Execution
Form Factor |
Tower |
Number of phases
Specification |
1 phase input to ground with ground and 1-phase output from the ground |
Input parameters
Power |
3000 VA / 2700 W |
Input voltage |
220/230/240 |
Input voltage range |
110 - 300 |
Current frequency |
40 -70 Hz (auto-sensing) |
Phases |
one phase grounding |
Output parameters
Output voltage |
220/230/240 V ± 1% |
Form voltage |
pure sine wave |
Current frequency |
50/60 Hz ± 0,2% |
Automatic voltage regulation (AVR) |
Yes |
Switching time |
0 ms |
Power factor correction |
0,9 |
Harmonic voltage fluctuations |
<2% (linear load) and <5% (with a non-linear load) |
Crest factor |
3:1 |
Protection and UPS equipment
Surge Protection |
Yes |
Overload protection |
Yes |
UPS Login |
Circuit breaker |
Short circuit |
Immediate load shedding or tripping of upstream circuit breaker |
Protect the phone, fax, modem, LAN |
1 x RJ11 / RJ45 |
Ports and interfaces
Dry contacts |
Yes |
USB-port |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
RS-232 |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
Port emergency shutdown EPO |
Yes |
SNMP |
Built-in expansion slot for SNMP adapter |
Connections of the generator input |
No |
Parallel UPS connection |
Optionally |
Battery
A type |
Lead-acid, sealed, maintenance-free |
Voltage and battery capacity |
12V / 9AH x 6 |
Typical recharge time |
8 hours (up to 90% of full battery capacity) |
Charging Current (Max) |
1A |
Estimated battery backup time (at 50% load) |
- |
Estimated battery backup time (at 100% load) |
- |
Hot-swappable batteries |
No |
Connecting additional battery cabinets |
Yes |
Cold start |
Yes |
Battery protection |
Automatic diagnostics, protection against overcharge and short-circuit |
Physical parameters
Output connectors |
- |
Dimensions (W * D * B) mm |
190x452x341 |
Weight, kg |
26,6 |
Indication |
LED and LCD-display (input / output voltage, frequency input / output voltage Operating modes: normal, bypass, battery power, battery level, load level) |
Sound alarm |
Beep in battery mode, when the battery is low, overload and fault charger |
Case features
Material |
Metal (0.5 mm) |
Environmental Parameters
Acoustic noise |
<50 dB (at 1 meter from surface) |
Working conditions |
Humidity 0 ~ 95% non-condensing, temperature 0 ~ 40? C |
Guarantee
Standard warranty |
1 year |
Todas las secciones
ACÚSTICA Y MULTIMEDIA
PERIFÉRICOS
UPS
SOLUCIONES CORPORATIVAS
Austria
Croacia
Inglaterra
Kazajstán
España
Republica checa
Francia
Polonia
Turquia
Bulgaria
Alemania
Alemania
Italia
Ucrania
Ucrania
Rusia
Bielorrusia
Estados Unidos
Canadá
Kuwait
Líbano
Arabia Saudita
EAU
Argelia
Kenia
Nigeria
Sudáfrica
China
Pakistán
Australia
China
India 





































Altavoces 2.0
Altavoces 2.1
Altavoces bluetooth
Digital consoles
Cables de datos
Dispositivo de carga
Batería del acumulador