CMUS-902RT
Features:
- LCD-display
- Pure sine output
- Case type universal (TOWER & RACK)
- UPS On-line class
- PF - 0.9
- On Self Test
- Cold start
- Microprocessor control
- Wide input voltage range
- Adapting to the current input frequency
- Intelligent management of the UPS cooling
- Adjustable battery charge current
- Various line-up of outlets
- The presence of EPO plugs for quick emergency power off
- Availability management ports: USB, RS-232, SNMP, RJ-11/45
- Protection against short-circuit, overload and other interference in the input power
- Charge the battery when the UPS is off
- Connecting additional battery kakbinetov
- Have UPS Isolation Transformer
Where to buy
|
|
Technology
UPS Type |
On-line |
Execution
Form Factor |
Universal (installation in 19 '' rack or on the floor) (Tower & Rack) |
Number of phases
Specification |
1 phase input to ground with ground and 1-phase output from the ground |
Input parameters
Power |
2000 VA / 1800 W |
Input voltage |
220/230/240 |
Input voltage range |
115 - 295 |
Current frequency |
45 -65 Hz (auto-sensing) |
Phases |
one phase grounding |
Output parameters
Output voltage |
220/230/240 V ± 1% |
Form voltage |
pure sine wave |
Current frequency |
50/60 Hz ± 0,2% |
Automatic voltage regulation (AVR) |
Yes |
Switching time |
0 ms |
Power factor correction |
0,9 |
Harmonic voltage fluctuations |
<3% (linear load) and <5% (with a non-linear load) |
Crest factor |
3:1 |
Protection and UPS equipment
Surge Protection |
Yes |
Overload protection |
Yes |
UPS Login |
Circuit breaker |
Short circuit |
Immediate load shedding or tripping of upstream circuit breaker |
Protect the phone, fax, modem, LAN |
1 x RJ11 / RJ45 |
Ports and interfaces
Dry contacts |
Yes |
USB-port |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
RS-232 |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
Port emergency shutdown EPO |
Yes |
SNMP |
Built-in expansion slot for SNMP adapter |
Connections of the generator input |
No |
Parallel UPS connection |
Optionally |
Battery
A type |
Lead-acid, sealed, maintenance-free |
Voltage and battery capacity |
12V / 9AH x 4 |
Typical recharge time |
8 hours (up to 90% of full battery capacity) |
Charging Current (Max) |
1A |
Estimated battery backup time (at 50% load) |
- |
Estimated battery backup time (at 100% load) |
- |
Hot-swappable batteries |
No |
Connecting additional battery cabinets |
Yes |
Cold start |
Yes |
Battery protection |
Automatic diagnostics, protection against overcharge and short-circuit |
Physical parameters
Output connectors |
- |
Dimensions (W * D * B) mm |
440x630x88 2U |
Weight, kg |
23,4 |
Indication |
LED and LCD-display (input / output voltage, frequency input / output voltage Operating modes: normal, bypass, battery power, battery level, load level) |
Sound alarm |
Beep in battery mode, when the battery is low, overload and fault charger |
Case features
Material |
Metal (0.5 mm) |
Environmental Parameters
Acoustic noise |
<50 dB (at 1 meter from surface) |
Working conditions |
Humidity 0 ~ 95% non-condensing, temperature 0 ~ 40? C |
Guarantee
Standard warranty |
1 year |
Todas las secciones
ACÚSTICA Y MULTIMEDIA
PERIFÉRICOS
UPS
SOLUCIONES CORPORATIVAS