In compare 0 items

CMUOA-650 Solar-M-3K

This series UPS is designed to protect a variety of equipment that works as part of a solar panel inverter.†UPS can operate with two types of PWM and MPPT inverters, allowing them to be univarsalnymi in this class.

Features:

  • LCD-display
  • Microprocessor control
  • Case type (RACK) for installation in the rack cabinet
  • Support for operation with solar inverters 2 types: PWM and MPPT
  • Support UPS operating mode of the DSU
  • Pure sine output
  • Various line-up of outlets
  • UPS On-line class
  • PF - 0.8
  • On Self Test
  • Cold start
  • Microprocessor control
  • Wide input voltage range
  • Adjustable battery charge current
  • Signal programming function for dry contacts (AS-400)
  • Protection against short-circuit, overload and other interference in the input power
  • Charge the battery when the UPS is off
  • Connecting additional battery kakbinetov
  • The presence of EPO plugs for quick emergency power off
  • Availability management ports: USB, RS-232, SNMP, RJ-11/45



Where to buy


Acquire

To purchase this product and delivery methods
contact your sales specialist.
Rely on professionals!


Sales department


Presentations

Check out the range of our products in the presentation section.
If you have any questions, please contact a sales specialist.

View presentation

Technology

UPS Type

On-line

execution

Form Factor

Installation in 19 '' rack (Rack)

Number of phases

Specification

1 phase input to ground with ground and 1-phase output from the ground

Input parameters

Power

3000VA / 2400W

Input voltage

220/230/240

Input voltage range

110 - 300

Current frequency

40 -70 Hz (auto sensing)

Phases

one phase grounding

Output parameters

Output voltage

220/230/240 V ± 1%

Form voltage

pure sine wave

Current frequency

50/60 Hz ± 0,3%

Automatic voltage regulation (AVR)

Yes

switching time

0 ms

Power factor correction

0,8

Harmonic voltage fluctuations

<3% (linear load) and <5% (with a non-linear load)

Crest factor

3:1

Protection and UPS equipment

Surge Protection

Yes

Overload protection

Yes

UPS Login

Circuit breaker

Short circuit

Immediate load shedding or tripping of upstream circuit breaker

Protect the phone, fax, modem, LAN

No

Ports and interfaces

Dry contacts

No

USB-port

Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages

RS-232

Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages

RS-485

Optionally

Port emergency shutdown EPO

Yes

SNMP

No

Connections of the generator input

Yes

Parallel UPS connection

No

Voltage and battery capacity

-

Typical recharge time

4 hours (up to 90% of full battery capacity)

Charging Current (Max)

10A

Estimated battery backup time (at 50% load)

-

Estimated battery backup time (at 100% load)

-

Hot-swappable batteries

No

Connecting additional battery cabinets

No

Cold start

Yes

battery protection

Automatic diagnostics, protection against overcharge and short-circuit

Characteristics of solar inverter

A type

MPPT

Maximum input power

3.0 kW

Charging Current (Max)

60.0 A

UPS inverter + BAT total charging current (Max)

70.0 A

Input Voltage (DC)

145

Physical parameters

Output connectors

3 x IEC-320 C13 with redundant power and filtration

Dimensions (W * D * B) mm

380x440x88 2U

Weight, kg

10

Indication

LED and LCD-display (input / output voltage, frequency input / output voltage Operating modes: normal, bypass, battery power, battery level, load level)

Sound alarm

Beep in battery mode, when the battery is low, overload and fault charger

Case features

Material

Metal (0.5 mm)

Environmental Parameters

Acoustic noise

<50 dB (at 1 meter from surface)

Working conditions

Humidity 0 ~ 95% non-condensing, temperature -5 ~ 45? C

Guarantee

standard warranty

1 year

Todas las secciones