In compare 0 items

Elego

Features:

  • Programmable supply priority for PV, Battery or Grid
  • User-adjustable battery charging current suits different types of batteries
  • Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
  • Built-in timer for various mode of on/off operation
  • Multiple communication for USB, RS-232, Modbus and SNMP
  • Monitoring software for real-time status display and control
  • Overload and short circuit protection
  • MPPT solar
  • Monitoring software included
  • Cold start function
  • Auto frequency range 0 to 5000
  • Thermal Protection Sensor



Where to buy Compare
MODEL Elego Solar-EOI 3P 10KW
Phase 3-phase in/3-phase out
Maximum PV Input Power 14850 W
Rated Output Power 10000 W
Maximum Charging Power 9600 W
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage 320 VDC / 350 VDC
Start-up Voltage / Initial Feeding Voltage 320 VDC / 350 VDC
MPP Voltage Range 400 VDC ~ 800 VDC
Number of MPP Trackers / Maximum Input Current 2 / 2 x 18.6A
GRID OUTPUT (AC)
Nominal Output Voltage 184 - 265 VAC* per phase
Nominal Output Current 14.5A per phase
Power Factor > 0.99
EFFICIENCY
Maximum Conversion Efficiency (DC/AC) 96%
European Efficiency@ Vnominal 95%
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage 120 - 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range 170 - 280 VAC per phase
Maximum AC Input Current 30A 40 A
PV INPUT (DC)
Maximum DC Voltage 900 VDC
MPP Voltage Range 400 VDC ~ 800 VDC
Number of MPP Trackers / Maximum Input Current 2 / 2 x 18.6A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 202/208/220/230/240 VAC
Output Waveform Pure sine wave
Efficiency (DC to AC) 93%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage 320 VDC / 350 VDC
MPPT Voltage Range 400 VDC ~ 800 VDC
Number of MPP Trackers / Maximum Input Current 2 / 2 x 18.6A
GRID OUTPUT (AC)
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range 184 - 265 VAC* per phase
Nominal Output Current 14.5A per phase
AC INPUT
AC Start-up Voltage / Auto Restart Voltage 120 - 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range 170 - 280 VAC per phase
Maximum AC Input Current 40 A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 230 VAC (P-N) / 400 VAC (P-P)
BATTERY & CHARGER
Nominal DC Voltage 48 VDC
Maximum Charging Current Default 60A, 10A - 200A (Adjustable)
GENERAL
PHYSICAL
Dimension, D X W X H (mm) 167.2 x 500 x 622
Net Weight (kgs) 45
INTERACE
Communication Port RS-232/USB and CAN Interface
ENVIRONMENT
Humidity 0 ~ 90% RH (No condensing)
Operating Temperature -10 to 55°C
Altitude 0 ~ 1000 m**

All sections