CMUS-9060H
Features:
- LCD-display
- Pure sine output
- Case type (TOWER)
- UPS On-line class
- PF - 0.9
- On Self Test
- Cold start
- Microprocessor control
- Wide input voltage range
- Connecting to the power supply input with 2 independent lines
- Adaptation to the current frequency mode
- Convection mode current frequencies
- Low coefficient of the input current waveform garmonitcheskih
- Built-in maintenance bypass
- Adjustable battery charge current
- The presence of EPO plugs for quick emergency power off
- Availability management ports: USB, RS-485, RS-232, SNMP, AS-400
- Protection against short-circuit, overload and other interference in the input power
- Connecting additional battery cabinets
- A parallel operation function
- Active power factor correction on all phases
- Support UPS operating mode of the DSU
- There is an isolation transformer with galvanic isolation
Vertriebspartner
|
|
Technology
UPS Type |
On-line |
Execution
Form Factor |
Tower |
Number of phases
Specification |
3 phase input to ground and 3-phase input with ground |
Input parameters
Power |
60.0 kW / 54.0 kW |
Input voltage |
380/400/415 V |
Input voltage range |
242 - 520 |
Current frequency |
40 - 70 Hz (auto-sensing) |
Output parameters
Output voltage |
380/400/415 V ± 1% |
Form voltage |
pure sine wave |
Current frequency |
50/60 Hz ± 0,5% |
Automatic voltage regulation (AVR) |
Yes |
Switching time |
0 ms |
Power factor correction |
0,98 |
Harmonic voltage fluctuations |
<1% (linear load) and <3% (with a non-linear load) |
Crest factor |
3:1 |
Protection and UPS equipment
Surge Protection |
Yes |
Overload protection |
Yes |
UPS Login |
Circuit breaker |
Short circuit |
Immediate load shedding or tripping of upstream circuit breaker |
Protect the phone, fax, modem, LAN |
No |
Ports and interfaces
Dry contacts |
Yes |
USB-port |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
RS-232 |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
RS-485 |
Yes |
Port emergency shutdown EPO |
Yes |
SNMP |
Built-in expansion slot for SNMP adapter |
Connections of the generator input |
Optionally |
Parallel UPS connection |
Optionally |
Battery
A type |
Lead-acid, sealed, maintenance-free |
Voltage and battery capacity |
No (only for ext. Battery cabinet) |
Typical recharge time |
9:00 (up to 90% of full battery capacity) |
Charging Current (Max) |
1,0 - 24,0 A |
Estimated battery backup time (at 50% load) |
- |
Estimated battery backup time (at 100% load) |
- |
Hot-swappable batteries |
No |
Connecting additional battery cabinets |
Yes |
Cold start |
Yes |
Battery protection |
Automatic diagnostics, protection against overcharge and short-circuit |
Physical parameters
Output connectors |
3Ph + N + GND terminal block input, 3Ph + N + GND terminal block to the output connector for ext.†battery cabinets |
Dimensions (W * D * B) mm |
600x800x1360 |
Weight, kg |
250.0 |
Indication |
LED and LCD-display (input / output voltage, frequency input / output voltage Operating modes: normal, bypass, battery power, battery level, load level) |
Sound alarm |
Beep in battery mode, when the battery is low, overload and fault charger |
Features
meterial |
Metal |
Protection class |
IP20 |
Environmental Parameters
Acoustic noise |
<60 dB (at 1 meter from surface) |
Working conditions |
Humidity 0 ~ 95% non-condensing, temperature 0 ~ 40? C |
Guarantee
Standard warranty |
1 year |
Der gesamte Katalog
Acoustics & Multimedia
IT Peripherals
Cartridges
UPS
Corporate solutions

Österreich
Kroatien
England
Kasachstan
Spanien
Tschechien
Frankreich
Polen
Türkei
Bulgarien
Deutschland
Deutschland
Italien
Ukraine
Ukraine
Russland
Weissrussland
USA
Kanada
Kuweit
Libanon
Saudi Arabien
VAE
Algerien
Kenia
Nigeria
Südafrika
China
Pakistan
Australien
China
Indien 




































Speakers 2.1
Bluetooth speakers
Digital consoles
Data cables
Charging device
Accumulator battery