CMUS-90120H
Features:
- LCD-display
- Pure sine output
- Case type (TOWER)
- UPS On-line class
- PF - 0.9
- On Self Test
- Cold start
- Microprocessor control
- Wide input voltage range
- Connecting to the power supply input with 2 independent lines
- Adaptation to the current frequency mode
- Convection mode current frequencies
- Low coefficient of the input current waveform garmonitcheskih
- Built-in maintenance bypass
- Adjustable battery charge current
- The presence of EPO plugs for quick emergency power off
- Availability management ports: USB, RS-485, RS-232, SNMP, AS-400
- Protection against short-circuit, overload and other interference in the input power
- Connecting additional battery cabinets
- A parallel operation function
- Active power factor correction on all phases
- Support UPS operating mode of the DSU
- There is an isolation transformer with galvanic isolation
Vertriebspartner
|
|
Technology
UPS Type |
On-line |
Execution
Form Factor |
Tower |
Number of phases
Specification |
3 phase input to ground and 3-phase input with ground |
Input parameters
Power |
120.0 kW / 108.0 kW |
Input voltage |
380/400/415 V |
Input voltage range |
242 - 520 |
Current frequency |
40 - 70 Hz (auto-sensing) |
Output parameters
Output voltage |
380/400/415 V ± 1% |
Form voltage |
pure sine wave |
Current frequency |
50/60 Hz ± 0,5% |
Automatic voltage regulation (AVR) |
Yes |
Switching time |
0 ms |
Power factor correction |
0,98 |
Harmonic voltage fluctuations |
<1% (linear load) and <3% (with a non-linear load) |
Crest factor |
3:1 |
Protection and UPS equipment
Surge Protection |
Yes |
Overload protection |
Yes |
UPS Login |
Circuit breaker |
Short circuit |
Immediate load shedding or tripping of upstream circuit breaker |
Protect the phone, fax, modem, LAN |
No |
Ports and interfaces
Dry contacts |
Yes |
USB-port |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
RS-232 |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
RS-485 |
Yes |
Port emergency shutdown EPO |
Yes |
SNMP |
Built-in expansion slot for SNMP adapter |
Connections of the generator input |
Optionally |
Parallel UPS connection |
Optionally |
Battery
A type |
Lead-acid, sealed, maintenance-free |
Voltage and battery capacity |
No (only for ext. Battery cabinet) |
Typical recharge time |
9:00 (up to 90% of full battery capacity) |
Charging Current (Max) |
1,0 - 48,0 A |
Estimated battery backup time (at 50% load) |
- |
Estimated battery backup time (at 100% load) |
- |
Hot-swappable batteries |
No |
Connecting additional battery cabinets |
Yes |
Cold start |
Yes |
Battery protection |
Automatic diagnostics, protection against overcharge and short-circuit |
Physical parameters
Output connectors |
3Ph + N + GND terminal block input, 3Ph + N + GND terminal block to the output connector for ext.†battery cabinets |
Dimensions (W * D * B) mm |
600x800x1680 |
Weight, kg |
414 |
Indication |
LED and LCD-display (input / output voltage, frequency input / output voltage Operating modes: normal, bypass, battery power, battery level, load level) |
Sound alarm |
Beep in battery mode, when the battery is low, overload and fault charger |
Features
meterial |
Metal |
Protection class |
IP20 |
Environmental Parameters
Acoustic noise |
<60 dB (at 1 meter from surface) |
Working conditions |
Humidity 0 ~ 95% non-condensing, temperature 0 ~ 40? C |
Guarantee
Standard warranty |
1 year |
Der gesamte Katalog