CMUOA-600E-15U-90
Features:
- LCD-display
- Pure sine output
- Case type (TOWER - Modular)
- UPS On-line class
- PF - 1.0
- On Self Test
- Cold start
- High overload capacity
- Microprocessor control
- Wide input voltage range
- Short MTTR
- Built-in maintenance bypass
- Adjustable battery charge current
- Capacity UPS power at the expense of additional power modules
- The presence of EPO plugs for quick emergency power off
- Availability management ports: USB, RS-232 and SNMP
- Connecting additional battery cabinets
- Protection against short-circuit, overload and other interference in the input power
- A parallel operation function
Vertriebspartner
|
|
Technology
UPS Type |
On-line |
Execution
Form Factor |
Tower (Modular) |
Number of phases
Specification |
3 phase input to ground and 3-phase output to ground |
Input parameters
Power |
3 x 30 kVA / 90 kW |
Input voltage |
380/400/415 V |
Input voltage range |
305 - 478 The |
Current frequency |
40 -70 Hz (auto-sensing) |
Phases |
3-phase output to ground |
Output parameters
Output voltage |
380/400/415 V ± 1% |
Form voltage |
pure sine wave |
Current frequency |
50/60 Hz ± 0,1% |
Automatic voltage regulation (AVR) |
Yes |
Switching time |
0 ms |
Power factor correction |
1 |
Harmonic voltage fluctuations |
<1.5% (linear load) and <4% (for non-linear load) |
Crest factor |
3:1 |
Protection and UPS equipment
Surge Protection |
Yes |
Overload protection |
Yes |
UPS Login |
Circuit breaker |
Short circuit |
Immediate load shedding or tripping of upstream circuit breaker |
Protect the phone, fax, modem, LAN |
No |
Ports and interfaces
Dry contacts |
Optionally |
USB-port |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
RS-232 |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
Port emergency shutdown EPO |
Yes |
SNMP |
Built-in expansion slot for SNMP adapter |
Connections of the generator input |
No |
Parallel UPS connection |
No |
Battery
A type |
Lead-acid, sealed, maintenance-free |
Voltage and battery capacity |
12V / 9AH x 120 |
Typical recharge time |
8 hours (up to 90% of full battery capacity) |
Charging Current (Max) |
8A |
Estimated battery backup time (at 50% load) |
- |
Estimated battery backup time (at 100% load) |
- |
Hot-swappable batteries |
No |
Connecting additional battery cabinets |
Yes |
Cold start |
Yes |
Battery protection |
Automatic diagnostics, protection against overcharge and short-circuit |
Physical parameters
Output connectors |
- |
Dimensions (W * D * B) mm |
514 x 1000 x 763 (UPS);†514 x 1000 x 610 (BAT) |
Weight, kg |
582 |
Indication |
LED and LCD-display (input / output voltage, frequency input / output voltage Operating modes: normal, bypass, battery power, battery level, load level) |
Sound alarm |
Beep in battery mode, when the battery is low, overload and fault charger |
Case features
meterial |
Metal |
Protection class |
IP20 |
Environmental Parameters
Acoustic noise |
<55 dB (at 1 meter from surface) |
Working conditions |
Humidity 0 ~ 95% non-condensing, temperature 0 ~ 40? C |
Guarantee
Standard warranty |
1 year |