CMUOA-650 Solar-M-3K
CMUOA-650 Solar-M-3K
Features:
- LCD-display
- Microprocessor control
- Case type (RACK) for installation in the rack cabinet
- Support for operation with solar inverters 2 types: PWM and MPPT
- Support UPS operating mode of the DSU
- Pure sine output
- Various line-up of outlets
- UPS On-line class
- PF - 0.8
- On Self Test
- Cold start
- Microprocessor control
- Wide input voltage range
- Adjustable battery charge current
- Signal programming function for dry contacts (AS-400)
- Protection against short-circuit, overload and other interference in the input power
- Charge the battery when the UPS is off
- Connecting additional battery kakbinetov
- The presence of EPO plugs for quick emergency power off
- Availability management ports: USB, RS-232, SNMP, RJ-11/45
Where to buy Compare
|
|
Technology
UPS Type |
On-line |
execution
Form Factor |
Installation in 19 '' rack (Rack) |
Number of phases
Specification |
1 phase input to ground with ground and 1-phase output from the ground |
Input parameters
Power |
3000VA / 2400W |
Input voltage |
220/230/240 |
Input voltage range |
110 - 300 |
Current frequency |
40 -70 Hz (auto sensing) |
Phases |
one phase grounding |
Output parameters
Output voltage |
220/230/240 V ± 1% |
Form voltage |
pure sine wave |
Current frequency |
50/60 Hz ± 0,3% |
Automatic voltage regulation (AVR) |
Yes |
switching time |
0 ms |
Power factor correction |
0,8 |
Harmonic voltage fluctuations |
<3% (linear load) and <5% (with a non-linear load) |
Crest factor |
3:1 |
Protection and UPS equipment
Surge Protection |
Yes |
Overload protection |
Yes |
UPS Login |
Circuit breaker |
Short circuit |
Immediate load shedding or tripping of upstream circuit breaker |
Protect the phone, fax, modem, LAN |
No |
Ports and interfaces
Dry contacts |
No |
USB-port |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
RS-232 |
Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
RS-485 |
Optionally |
Port emergency shutdown EPO |
Yes |
SNMP |
No |
Connections of the generator input |
Yes |
Parallel UPS connection |
No |
Voltage and battery capacity |
- |
Typical recharge time |
4 hours (up to 90% of full battery capacity) |
Charging Current (Max) |
10A |
Estimated battery backup time (at 50% load) |
- |
Estimated battery backup time (at 100% load) |
- |
Hot-swappable batteries |
No |
Connecting additional battery cabinets |
No |
Cold start |
Yes |
battery protection |
Automatic diagnostics, protection against overcharge and short-circuit |
Characteristics of solar inverter
A type |
MPPT |
Maximum input power |
3.0 kW |
Charging Current (Max) |
60.0 A |
UPS inverter + BAT total charging current (Max) |
70.0 A |
Input Voltage (DC) |
145 |
Physical parameters
Output connectors |
3 x IEC-320 C13 with redundant power and filtration |
Dimensions (W * D * B) mm |
380x440x88 2U |
Weight, kg |
10 |
Indication |
LED and LCD-display (input / output voltage, frequency input / output voltage Operating modes: normal, bypass, battery power, battery level, load level) |
Sound alarm |
Beep in battery mode, when the battery is low, overload and fault charger |
Case features
Material |
Metal (0.5 mm) |
Environmental Parameters
Acoustic noise |
<50 dB (at 1 meter from surface) |
Working conditions |
Humidity 0 ~ 95% non-condensing, temperature -5 ~ 45? C |
Guarantee
standard warranty |
1 year |
All sections
Acoustics & Multimedia
IT Peripherals
Cartridges
UPS
Corporate solutions