CMUS-610R
Features:
- LCD-display
- Pure sine output when running on battery
- Case type (TOWER)
- PF - 0.9
- Line Interactive UPS Class
- On Self Test
- Cold start
- Auto power when the input voltage voostanovlenii network
- Charge the battery when the UPS is off
- Protection against short-circuit, overload and other interference in the input power
- Stabilization of high and low input voltage
- Adaptatiya to the current frequency
- Adjustable battery charge current
- ECO mode (turn off the UPS with no load)
- Various line-up of outlets
- Availability management ports: USB, RS-232, SNMP, RJ-11/45
- The presence of EPO plugs for quick emergency power off
Where to buy Compare
|
|
Technology
UPS Type |
Line Interactive |
Execution
Form Factor |
Universal (installation in 19 '' rack or on the floor) (Tower & Rack) |
Number of phases
Specification |
1 phase input to ground with ground and 1-phase output from the ground |
Input parameters
Power |
1000VA / 800W |
Input voltage |
208/220/230 / 240V |
Input voltage range |
165 - 300 |
Current frequency |
50/60 Hz ± 10% (auto sensing) |
Output parameters
Output voltage |
220/230 / 240V ± 5% |
Form voltage |
Pure Sine Wave |
Current frequency |
50/60 Hz ± 0.3% |
Switching time |
less than 10 ms, including the determination of the time |
Harmonic current oscillations |
<5% (linear load) |
Crest factor |
3:1 |
Protection and UPS equipment
Surge Protection |
Yes |
UPS protection against overloads |
Yes |
Protection for UPS input |
Circuit breaker |
UPS protection for short circuit |
Immediate shutdown of the UPS, or protection by means of the input circuit breaker |
Protect the phone, fax, modem, LAN |
2 x RJ45 |
Ports and interfaces
USB-port |
Indication of low battery power, the voltage at the input / output load power management on / off UPS |
SNMP-card |
Optionally |
Battery
A type |
Lead acid, sealed, maintenance-free |
Voltage and battery capacity |
12V / 7AH x 2 |
Typical recharge time |
4 hours (up to 90% of full battery capacity) |
Estimated battery backup time (at 50% load) |
- |
Estimated battery backup time (at 100% load) |
- |
Connecting additional battery |
Yes |
Cold start |
Yes |
Battery protection |
Automatic verification and protection of critical discharge on LCD-display Battery replacement indicator |
Physical parameters
Output connectors |
6 x IEC-320 C13 with redundant power and filtration, or 3 x EURO with redundant power and filtration |
Physical parameters
UPS Dimensions (W * D * B) mm |
338x440x88 (2U) |
Packing dimensions (W * D * B) mm |
448x611x208 |
Weight, kg |
14,6 |
Gross Weight |
16,8 |
Indication |
LED and LCD-display |
Sound alarm |
Standby mode - a rare acoustic signal (1 every 5 seconds, then repeat every 60 seconds);†low battery level - sound beeps (last 16 seconds);†overload - a very special sound signal (every 2 seconds); |
Case features
Material |
Metal (0.5 mm) |
Environmental Parameters
Acoustic noise |
<50 dB (1 meter from the surface) |
Working conditions |
Humidity 0% to 90% non-condensing, temperature: 0 ~ 40 ?C |
Guarantee
Standard warranty |
1 year |
All sections
Acoustics & Multimedia
IT Peripherals
Cartridges
UPS
Business solutions