In compare 0 items

new CMUS - 9020

This UPS series is designed for places where the three-phase input and single phase output, thereby providing centralized protection for various critical equipment with capacity up to 30kVA.†UPS system with three phase input and single-phase output allows you to load more evenly industrial network, using all three phases.

Features:

  • LCD-display
  • Pure sine output
  • Case type (TOWER)
  • UPS On-line class
  • PF - 0.9
  • On Self Test
  • Cold start
  • Microprocessor control
  • Wide input voltage range
  • We solve the adaptation to the current frequency
  • Convection mode current frequencies
  • Adjustable battery charge current
  • The presence of EPO plugs for quick emergency power off
  • Availability management ports: USB, RS-232, SNMP
  • Protection against short-circuit, overload and other interference in the input power
  • Connecting additional battery cabinets
  • A parallel operation function



Where to buy Compare

Main advantages:

  • The best of the best. UPS SMART UPS Pro not only have the best characteristics of the UPS UPS in its class, but also the best performance.
  • The price and quality. Through years of experience manufacturing UPS, the CROWN company uses a special power components assembly technology, which allows to optimize production processes and to create On-Line UPS UPS with double-conversion maximum performance at an affordable price. Multi-level quality control system allows the company to produce equipment at international standards.

Additionally!

  • Technology - On-Line; (Continuous - online double conversion) .
  • Pure sine wave output with zero transfer time of backup.
  • Fully microprocessor control.
  • High-quality filtering pomex.
  • Automatic and safe shutdown of the operating system.
  • Remote control / monitoring via the panel board RS-232 and USB relays and communication interface.
  • The use of external battery packs to increase the backup time.

Monitoring and management:

  • The basis CMUS - SMART 9020 is "intelligent" control logic is controlled by a microprocessor. All functions are performed by a microprocessor, which controls and maintains the special operating conditions in memory.
  • On the back of the UPS UPS is RS232 port through which the remote control operation and / or transmission of logic signals to computers equipped with special equipment and software. This allows real time control of operating parameters and any anomaly (failure) in.
  • Software: with it you can access to all production data CMUS - 9020 SMART. It also allows you to configure special features, as well as manage the shutdown of Windows and Linux operating systems.

The software allows:

  • Monitor the status of the UPS UPS (input and output characteristics of the battery condition, the overall experience in working / off / emergency modes, temperature).
  • Conduct UPS configuration UPS (output characteristics, module redundancy N + x, battery, bypass, neutral sensor, the current time).
  • View events that are in the memory of the UPS UPS, for example, the completion of battery life, overheating alarm, etc. with the time and date.
  • Perform programming UPS UPS (on / off setting).
  • Conduct testing UPS UPS (display, batteries).


Acquire

To purchase this product and delivery methods
contact your sales specialist.
Rely on professionals!


Sales department


Presentations

Check out the range of our products in the presentation section.
If you have any questions, please contact a sales specialist.

View presentation

Technology

UPS Type

On-line

Execution

Form Factor

Tower

Number of phases

Specification

3 phase input to ground and 3-phase input with ground

Input parameters

Power

20.0 kW / 18.0 kW

Input voltage

380/400/415 V

Input voltage range

242 - 520

Current frequency

40 - 70 Hz (auto-sensing)

Output parameters

Output voltage

380/400/415 V ± 1%

Form voltage

pure sine wave

Current frequency

50/60 Hz ± 0,5%

Automatic voltage regulation (AVR)

Yes

Switching time

0 ms

Power factor correction

0,98

Harmonic voltage fluctuations

<1% (linear load) and <3% (with a non-linear load)

Crest factor

3:1

Protection and UPS equipment

Surge Protection

Yes

Overload protection

Yes

UPS Login

Circuit breaker

Short circuit

Immediate load shedding or tripping of upstream circuit breaker

Protect the phone, fax, modem, LAN

No

Ports and interfaces

Dry contacts

Yes

USB-port

Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages

RS-232

Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages

RS-485

Yes

Port emergency shutdown EPO

Yes

SNMP

Built-in expansion slot for SNMP adapter

Connections of the generator input

Optionally

Parallel UPS connection

Optionally

Battery

A type

Lead-acid, sealed, maintenance-free

Voltage and battery capacity

12V / 9AH x 64

Typical recharge time

9:00 (up to 90% of full battery capacity)

Charging Current (Max)

1,0 - 12,0 A

Estimated battery backup time (at 50% load)

-

Estimated battery backup time (at 100% load)

-

Hot-swappable batteries

No

Connecting additional battery cabinets

Yes

Cold start

Yes

Battery protection

Automatic diagnostics, protection against overcharge and short-circuit

Physical parameters

Output connectors

3Ph + N + GND terminal block input, 3Ph + N + GND terminal block to the output connector for ext.†battery cabinets

Dimensions (W * D * B) mm

600x800x1360

Weight, kg

205.0

Indication

LED and LCD-display (input / output voltage, frequency input / output voltage Operating modes: normal, bypass, battery power, battery level, load level)

Sound alarm

Beep in battery mode, when the battery is low, overload and fault charger

—ase features

meterial

Metal

Protection class

IP20

Environmental Parameters

Acoustic noise

<60 dB (at 1 meter from surface)

Working conditions

Humidity 0 ~ 95% non-condensing, temperature 0 ~ 40? C

Guarantee

Standard warranty

1 year

All sections