CBTD 12V-5Ah
new CBTD 12V-5Ah
Applications
- All purpose
- Uninterruptable Power Supply(UPS)
- Electric Power System(EPS)
- Emergency back-up power supply
- Emergency light
- Railway signal
- Aircraft signal
- Alaram and security system
- Electronic apparatus and equipment
- Communication power supply
- DC power supply
- Auto control system
Where to buy Compare
|
|
Nominal Voltage | 12V | |
Nominal Capacity(20hr) | 5.0AH | |
Dimensions | ||
Length 151±2mm(5.94 inches) | ||
Width 53±1mm(2.09 inches) | ||
Container Height 93±1mm(3.66 inches) | ||
Total Height (with Terminal) 99±1mm(3.90 inches) | ||
Approx Weight | Approx 1.75 kg (3.86lbs) | |
Terminal | T1 | |
Container Material | ABS | |
Rated Capacity | ||
5.00AH/0.250A...... (20hr, 1.80V/cell,25°C/77°F) | ||
4.65AH/0.465A.....(10hr, 1.80V/cell,25°C/77°F) | ||
4.20AH/0.840A.....(5hr, 1.75V/cell,25°C/77°F) | ||
3.66AH/1.22A.....(3hr, 1.75V/cell,25°C/77°F) | ||
3.04AH/3.04A.....(1hr, 1.60V/cell,25°C/77°F) | ||
Max.Discharge current | 75A (5s) | |
Internal Resistance | Approx 45mU | |
Operating Temp Range | ||
Discharge: -15~50°C(5~122°F) | ||
Charge: -0~40°C(32~104°F) | ||
Storage: -15~40°C(5~104°F) | ||
Nominal Operating Temp.Range | 25±3°C(77±5°F) | |
Cycle Use | ||
Intial Charging Current Voltage | ||
14.4V~15.0V at25°C(77°F)Temp.Coefficient-30mV/°C | ||
Standby Use | ||
No limit on Intial Charging Curent Voltage | ||
13.5V~13.8V at25°C(77°F)Tep.Coefficient -20mV/°C | ||
Capacity affected by Temperature | ||
40°C (104°F) 103% | ||
25°C (77°F) 100% | ||
0°C (32°F) 86% | ||
Self Discharge | ||
Crown batteries may be stored for up to 6 months | ||
at 25°C(77°F) and then a freshing charge is required. | ||
For higher termeratures the time interval will be shorter. |
Constant Current Discharge (Amperes) at 25°C(77°F) | |||||||||||||||
F.V/Time | 5min | 10min | 15min | 20min | 30min | 45min | 1h | 2h | 3h | 4h | 5h | 6h | 8h | 10h | 20h |
1.85V/cell | 9.60 | 6.69 | 5.52 | 4.79 | 3.84 | 2.95 | 2.42 | 1.48 | 1.12 | 0.924 | 0.784 | 0.679 | 0.540 | 0.449 | 0.248 |
1.80V/cell | 11.8 | 7.99 | 6.40 | 5.42 | 4.24 | 3.22 | 2.60 | 1.57 | 1.18 | 0.971 | 0.818 | 0.709 | 0.560 | 0.465 | 0.250 |
1.75V/cell | 14.0 | 9.03 | 7.06 | 5.90 | 4.54 | 3.42 | 2.74 | 1.64 | 1.22 | 1.00 | 0.840 | 0.727 | 0.575 | 0.474 | 0.253 |
1.70V/cell | 15.9 | 9.96 | 7.64 | 6.33 | 4.77 | 3.55 | 2.85 | 1.70 | 1.26 | 1.03 | 0.861 | 0.744 | 0.584 | 0.482 | 0.257 |
1.65V/cell | 17.5 | 10.7 | 8.08 | 6.65 | 4.97 | 3.69 | 2.97 | 1.75 | 1.30 | 1.05 | 0.880 | 0.758 | 0.593 | 0.489 | 0.261 |
1.60V/cell | 18.4 | 11.2 | 8.42 | 6.86 | 5.11 | 3.77 | 3.04 | 1.81 | 1.33 | 1.07 | 0.898 | 0.773 | 0.606 | 0.497 | 0.262 |
Constant Power Discharge (Watts) at 25°C(77°F) | |||||||||||||||
F.V/Time | 5min | 10min | 15min | 20min | 30min | 45min | 1h | 2h | 3h | 4h | 5h | 6h | 8h | 10h | 20h |
1.85V/cell | 18.1 | 12.7 | 10.6 | 9.27 | 7.49 | 5.79 | 4.76 | 2.92 | 2.23 | 1.84 | 1.57 | 1.36 | 1.09 | 0.905 | 0.500 |
1.80V/cell | 22.0 | 15.1 | 12.2 | 10.4 | 8.23 | 6.27 | 5.09 | 3.09 | 2.33 | 1.93 | 1.63 | 1.41 | 1.12 | 0.931 | 0.503 |
1.75V/cell | 25.7 | 16.9 | 13.3 | 11.2 | 8.73 | 6.63 | 5.33 | 3.20 | 2.40 | 1.97 | 1.66 | 1.44 | 1.14 | 0.944 | 0.504 |
1.70V/cell | 28.9 | 18.4 | 14.3 | 12.0 | 9.12 | 6.84 | 5.52 | 3.31 | 2.47 | 2.01 | 1.69 | 1.47 | 1.15 | 0.954 | 0.510 |
1.65V/cell | 31.4 | 19.5 | 14.9 | 12.5 | 9.42 | 7.06 | 5.72 | 3.39 | 2.52 | 2.04 | 1.72 | 1.49 | 1.17 | 0.962 | 0.515 |
1.60V/cell | 32.5 | 20.1 | 15.4 | 12.7 | 9.58 | 7.15 | 5.80 | 3.47 | 2.56 | 2.08 | 1.75 | 1.51 | 1.18 | 0.974 | 0.515 |